Off-the-shelf & Custom Infrared Lens, thermal imaging cameras & systems components

Home / All / Thermal IR Optronics Related Components / Laser Range Finder /

Laser Range Finder 9V-16V 1535nm LRF G1535 3S

Home / All / Thermal IR Optronics Related Components / Laser Range Finder /

Laser Range Finder 9V-16V 1535nm LRF G1535 3S

Laser Range Finder 9V-16V 1535nm LRF G1535 3S

Laser Range Finder 9V-16V 1535nm LRF G1535 3S
CategoriesLaser Range Finder
BrandQuanhom Optronics
ModelLRF G1535 3S
Power Supply9V-16V
Continuous Ranging Frequency1-10Hz(adjustable)
Operating Temperature-40℃-+65℃
Update TimeApr 24,2024
Detail Information
  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications

Performance

Performance range [m]:

Continuous ranging frequency
adjustable from 1Hz to 10Hz
Wavelength
1535nm
Laser divergence Angle
≤0.5mrad
Accuracy Rate
≥98%
Ranging accuracy
≤±1m (RMS) 
Minimum range
≤50m
Ranging resolution
≤30m
Operating Temperature
-40℃~+65℃
Storage Temperature
-55℃~+70℃
Weight
≤55g
Size
≤51.5mm×26mm×41.5mm
Power Supply voltage
DC9V-16V
Power

average power consumption ≤1.5W, peak power consumption ≤5W

Communication interface
RS422, 115200bps
Rate of work
Average working rate≤1.5W, working efficiency≤5W
Download document
file name
type
download
PDF format
FAQ
Why the lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), which can be refocused

 

2. If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

 

3. Hardware problems, such as the potentiometer does not work, replace the hardware that does not work.

- Why cannot the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable

 

2. Replace the data cable, maybe the data cable is not compatible with the computer or the cable data is wrongly selected

 

3. Confirm the wiring of the module or the control board, maybe the wiring is loose

 

4. Module or control board hardware problem, replace the hardware.

APPLICATIONS
Airborne
Enhanced Vision
Homeland Security
Review