Off-the-shelf & Custom Infrared Lens, thermal imaging cameras & systems components

Home / All / LWIR Lens | Infrared Optics / Continuous Zoom LWIR Lens /

Auto Focus Infrared Lens 36-180mm f/0.85-1.2

Home / All / LWIR Lens | Infrared Optics / Continuous Zoom LWIR Lens /

Auto Focus Infrared Lens 36-180mm f/0.85-1.2

Auto Focus Infrared Lens 36-180mm f/0.85-1.2

Auto Focus Infrared Lens 36-180mm f/0.85-1.2
Auto Focus Infrared Lens 36-180mm f/0.85-1.2Auto Focus Infrared Lens 36-180mm f/0.85-1.2
CategoriesContinuous Zoom LWIR Lens
BrandQuanhom Optronics
ModelGCZ53612D
LWIR Lens36-180mm f/0.85-1.2
ApplicationsSecurity and Surveillance
Focus MechanismMotorized
Update TimeMar 19,2024
Detail Information
  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
25μm
/
/
2.7°-13.3°
3.1°-15.2°
/
/
/
/
20μm
/
/
2.1°-10.7°
2.4°-12.2°
4.1°-20.2°
4.1°-20.2°
/
/
17μm
/
/
1.8°-9.1°
2.1°-10.4°
3.5°-17.2°
3.5°-17.2°
/
/
12μm
/
/
1.3°-6.4°
1.5°-7.3°
2.4°-12.2°
2.4°-12.2°
/
/

Optical

Focal Length[mm]
36-180
F/#
0.85-1.2
Wavelength
8-12μm
Focus Range
5m-Infinity
Format
Φ14

Mechanical

Interface
Flange
Focus Mechanism
Motorized 
Dimensions [mm]
Φ182x241.85(Front flange Φ205)
Weight
<3700g

Environmental

Operating Temperature
-40℃ to +60
Storage Temperature
-40℃ to +80
External Coating
DLC
Front Element Sealing
IP67
Download document
FAQ
- Why is the LWIR Continuous Zoom Lens autofocus not clear?

There are many reasons why the lens autofocus is not clear; the main reasons are as follows which can be checked one by one:

1. During the focusing process, if there is a large moving target in the lens screen (occupying more than 1/3 of the picture), just refocus;

2. If the lens is used for a long time, and the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, adjust the module or control board parameters to make the focus clear again;

3. For hardware problems such as the potentiometer not working, replace the hardware that does not work.

- Why can not the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected; the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, which may be incompatible with the computer or of the wrong type;

3. Check if the wiring of the module or the control board is loose;

4. For module or control board hardware problems, replace the hardware.