Off-the-shelf & Custom Infrared Lens, thermal imaging cameras & systems components

Home / All / LWIR Lens | Infrared Optics / HD Lenses /

Motorized Continuous Zoom IR Lens 25mm-225mm f/0.85-1.3 F1.3 LWIR

Home / All / LWIR Lens | Infrared Optics / HD Lenses /

Motorized Continuous Zoom IR Lens 25mm-225mm f/0.85-1.3 F1.3 LWIR

Motorized Continuous Zoom IR Lens 25mm-225mm f/0.85-1.3 F1.3 LWIR

Motorized Continuous Zoom IR Lens 25mm-225mm f/0.85-1.3 F1.3 LWIR
CategoriesHD Lenses
BrandQuanhom Optronics
ModelGCZ92513KD
LWIR Lens25-225mm f/0.85-1.3
ApplicationsSecurity and Surveillance
Focus MechanismMotorized
Update TimeApr 26,2024
Detail Information
  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
25μm
/
/
/
2.4°-21.7°
/
/
6.5°-54.2°
/
17μm
/
/
1.5°-13°
1.7°-14.9°
2.8°-24.6°
2.8°-24.6°
4.4°-38.4°
/
12μm
/
/
1°-9.2°
1.2°-10.5°
2°-17.5°
2°-17.5°
3.1°-24.7°
3.9°-34.2°

Optical

Focal Length[mm]
25-225mm 9X Continuous Zoom
F/#
0.85-1.3
Wavelength
8-12µm

Focus Range

15m-Infinity

Format
Ø21.8

Mechanical

Interface
Flange
Focus Mechanism
Motorized
Dimensions [mm]
Ø206x 307.4(Front flange Φ235)
Weight
<6100g

Electrical & Communications

Power Input
DC 12V 
Communications
Optional

Environmental

Operating Temperature
-40℃ to +60
Storage Temperature
-40℃ to +80
External Coating
DLC
Front Element Sealing
IP67
Download document
FAQ
- Why is the lens autofocus not clear?

There are many reasons why the lens autofocus is not clearl; the main reasons are as follows which can be checked one by one:

1. During the focusing process, if there is a large moving target in the lens screen (occupying more than 1/3 of the picture), just refocus;

2. If the lens is used for a long time, and the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, adjust the module or control board parameters to make the focus clear again;

3. For hardware problems such as the potentiometer not working, replace the hardware that does not work.

- Why can not the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected; the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, which may be incompatible with the computer or of the wrong type;

3. Check if the wiring of the module or the control board is loose;

4. For module or control board hardware problems, replace the hardware.