Off-the-shelf & Custom Infrared Lens, thermal imaging cameras & systems components

Home / All / LWIR Lens | Infrared Optics / Continuous Zoom LWIR Lens /

LWIR Continuous Zoom Lens 15-100mm f/1.1-1.4

Home / All / LWIR Lens | Infrared Optics / Continuous Zoom LWIR Lens /

LWIR Continuous Zoom Lens 15-100mm f/1.1-1.4

LWIR Continuous Zoom Lens 15-100mm f/1.1-1.4

LWIR Continuous Zoom Lens 15-100mm f/1.1-1.4
CategoriesContinuous Zoom LWIR Lens
BrandQuanhom Optronics
ModelGCZ71514KD
GCZ71514KD15-100mm f/1.1-1.4
ApplicationsSecurity and Surveillance
Focus MechanismMotorized
Update TimeApr 28,2024
Detail Information
  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
25μm
2.3°-15.2°
4.6°-29.9°
4.8°-31.3°
5.5°-35.5°
/
/
/
/
17μm
1.6°-10.4°
3.1°-20.6°
3.3°-21.6°
3.7°-24.6°
6.2°-39.9°
6.2°-39.9°
/
/
12μm
1.1°-7.3°
2.2°-14.6°
2.3°-15.3°
2.6°-17.5°
4.4°-28.7°
4.4°-28.7°
7°-44.5°
8.8°-54.2°

Optical

Focal Length[mm]
15-100
F/#
1.1-1.4
Wavelength
8-12μm
Focus Range
5m-Infinity/15m-Infinity

Mechanical

Interface
Flange
Focus Mechanism
Motorized
Dimensions [mm]
Ø106x138
Weight
<1300g

Electrical & Communications

Power Input
DC 12V Average

Environmental

Operating Temperature
-40℃ to +85
Storage Temperature
-60℃ to +85
External Coating
DLC
Front Element Sealing
IP67
Download document
FAQ
- Why is the lens autofocus not clear?

There are many reasons why the lens autofocus is not clearl; the main reasons are as follows which can be checked one by one:

1. During the focusing process, if there is a large moving target in the lens screen (occupying more than 1/3 of the picture), just refocus;

2. If the lens is used for a long time, and the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, adjust the module or control board parameters to make the focus clear again;

3. For hardware problems such as the potentiometer not working, replace the hardware that does not work.

- Why can not the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected; the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, which may be incompatible with the computer or of the wrong type;

3. Check if the wiring of the module or the control board is loose;

4. For module or control board hardware problems, replace the hardware.

VIDEO
APPLICATIONS
Homeland Security
Maritime & Naval
Security & Surveillance
Review